These demonstrations use research imaging from The Cancer Imaging Archive, NCI Imaging Data Commons, KU Leuven, and the University of Leeds. The forearm CT and knee MRI are cadaveric specimens. Source coverage varies by study. They are for demonstration and education, not clinical use.
Each study includes its citation, license, source record, and details of any modifications. The forearm CT includes reduced-resolution imaging and derived coronal and sagittal series under CC BY-SA 4.0; adaptations of those images must retain that license. The knee MRI retains original image pixels with deidentified metadata under CC BY 4.0. The previews are rendered from the included images. Close this tab to return to your scan.
Lung and soft-tissue stacks, coronal and sagittal reconstructions, MIP, and scouts.
Citation
Cancer Moonshot Biobank (2022). Cancer Moonshot Biobank - Multiple Myeloma Collection (CMB-MML) [Dataset]. The Cancer Imaging Archive. https://doi.org/10.7937/szkb-sw39
Included imaging
6 source imaging series / 901 images. Lung and soft-tissue stacks, coronal and sagittal reconstructions, MIP, and scouts. All indexed imaging instances for this study are included. This does not establish that the original clinical examination was published in full.
Noncontrast and contrast axial images, with coronal and sagittal reconstructions.
Citation
National Cancer Institute Clinical Proteomic Tumor Analysis Consortium (CPTAC) (2018). The Clinical Proteomic Tumor Analysis Consortium Clear Cell Renal Cell Carcinoma Collection (CPTAC-CCRCC) [Dataset]. The Cancer Imaging Archive. https://doi.org/10.7937/k9/tcia.2018.oblamn27
Included imaging
7 source imaging series / 898 images. Noncontrast and contrast axial images, with coronal and sagittal reconstructions. All indexed imaging instances for this study are included. This does not establish that the original clinical examination was published in full. 4 accompanying RTSTRUCT objects are available separately; they are not part of the opening image ZIP.
KU Leuven cadaveric specimen 7. Distal forearm, wrist and hand with axial, coronal and sagittal derived series; supports bone reconstruction.
Citation
Quintiens et al. (2024), Multimodal CT Dataset of Cadaveric Wrist Joints, KU Leuven RDR, V1, DOI 10.48804/DWF4RG. Specimen 7, scan 1; derived compact imaging, CC BY-SA 4.0.
Included imaging
Cadaveric distal forearm, wrist and hand, 216.7 mm source span. 4x4x4 averaged axial series with orthogonal coronal and sagittal reformats. Does not include elbow.
3D T1 and T2, postcontrast T1, and FLAIR. This source examination does not include DWI/ADC.
Citation
Juvekar, Parikshit; Dorent, Reuben; Kögl, Fryderyk; Torio, Erickson; Barr, Colton; Rigolo, Laura; Galvin, Colin; Jowkar, Nick; Kazi, Anees; Haouchine, Nazim; Cheema, Harneet; Navab, Nassir; Pieper, Steve; Wells, William M.; Bi, Wenya Linda; Golby, Alexandra; Frisken, Sarah; Kapur, Tina (2023). The Brain Resection Multimodal Imaging Database (ReMIND) [Dataset]. The Cancer Imaging Archive. https://doi.org/10.7937/3rag-d070
Included imaging
5 source imaging series / 663 images. 3D T1 and T2, postcontrast T1, and FLAIR. This source examination does not include DWI/ADC. All indexed imaging instances for this study are included. This does not establish that the original clinical examination was published in full. 4 accompanying SEG objects are available separately; they are not part of the opening image ZIP.
Colorized PET and fused PET/CT over the CT’s shorter field of view. Explore 419 PET slices, linked planes, activity values, and 3D MIP.
Citation
Li, P., Wang, S., Li, T., Lu, J., HuangFu, Y., & Wang, D. (2020). A Large-Scale CT and PET/CT Dataset for Lung Cancer Diagnosis (Lung-PET-CT-Dx) [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/TCIA.2020.NNC2-0461
Included imaging
419 PET slices spanning 847 mm, plus 161 CT slices spanning 160 mm. Both source imaging series are complete as indexed by IDC, but the accompanying CT covers only part of the PET field. Shared DICOM coordinates support linked comparison within the overlap; this is not newly computed registration. Original DICOM bytes are unchanged. Values are source activity concentration in Bq/mL, not calculated SUV. Ancillary SEG/SR annotations are not included.
Three shoulder projections: axial and internal/external-rotation AP views.
Citation
The Research for Precision Oncology Program and the Applied Proteogenomics Organizational Learning and Outcomes (APOLLO) Research Network. (2024). VA Research Precision Oncology Program - APOLLO (VAREPOP-APOLLO) (Version 3) [Dataset]. The Cancer Imaging Archive. https://doi.org/10.7937/GHKN-MD15
Included imaging
All images from the selected public source study. Three shoulder projections: axial and internal/external-rotation AP views.